Request History Viewer
All
Request # CT03313

DateDescriptionAdditional Details
11/3/2006 1:02:52 PMPart 12577811 Cycles to Completion 
11/3/2006 1:02:52 PMRequest CT03313 Cycles to Completion 
11/3/2006 1:02:51 PMPart 12577811 ApprovedApproved by Tingle, James
11/3/2006 1:02:38 PMPart 12577811 ApprovedApproved by Tingle, James
11/3/2006 1:02:30 PMPart 12577811 ApprovedApproved by Tingle, James
11/3/2006 1:02:21 PMPart 12577811 ApprovedApproved by Tingle, James
11/3/2006 1:02:13 PMPart 12577811 ApprovedApproved by Tingle, James
11/3/2006 1:02:03 PMPart 12577811 ApprovedApproved by Tingle, James
10/30/2006 6:47:41 AMPart 12577811 ApprovedApproved by Tingle, James
10/30/2006 6:47:30 AMPart 12577811 ApprovedApproved by Tingle, James
10/26/2006 3:09:53 PMPart 12579139 Cycles to Completion 
10/26/2006 3:09:52 PMPart 12579139 ApprovedApproved by Laker, Andrew
10/26/2006 3:09:44 PMPart 12579139 ApprovedApproved by Laker, Andrew
10/26/2006 3:09:35 PMPart 12579139 ApprovedApproved by Laker, Andrew
10/26/2006 3:09:26 PMPart 12579139 ApprovedApproved by Laker, Andrew
10/26/2006 3:09:19 PMPart 12579139 ApprovedApproved by Laker, Andrew
10/25/2006 11:10:24 AMPTE item rework requested by Tingle, JamesPart=12577811, Component=Mold Plate / Insert, Item=C. The reason for rework request was: "'C' upper plate is okay. Rework lower plate by returning to original edge blends."
10/25/2006 11:09:56 AMPTE item rework requested by Tingle, JamesPart=12577811, Component=Mold Plate / Insert, Item=A. The reason for rework request was: "'A' upper plate is okay. Rework lower plate by returning to original edge blends. "
10/25/2006 11:07:53 AMPart 12577811 ApprovedApproved by Tingle, James
10/25/2006 11:07:42 AMPart 12577811 ApprovedApproved by Tingle, James
10/25/2006 11:07:31 AMPart 12577811 ApprovedApproved by Tingle, James
10/25/2006 11:07:20 AMPart 12577811 ApprovedApproved by Tingle, James
10/25/2006 11:07:01 AMPart 12577811 ApprovedApproved by Tingle, James
10/12/2006 11:38:57 AMDC McCullough, Alex cancelled item The reason for cancellation was: No change required on 'B' slides
10/12/2006 11:38:56 AMDC McCullough, Alex cancels item 
10/12/2006 11:37:29 AMDC McCullough, Alex cancelled item The reason for cancellation was: E does not have slides
10/12/2006 11:37:28 AMDC McCullough, Alex cancels item 
10/12/2006 11:36:45 AMDC McCullough, Alex cancels item 
10/12/2006 11:36:45 AMDC McCullough, Alex cancelled item The reason for cancellation was: F does not have slides
10/11/2006 9:18:08 AMPTE item rework requested by Laker, AndrewPart=12579139, Component=Slide Cavity, Item=F. The reason for rework request was: "F does not have slides. Remove from Tooling Component List."
10/11/2006 9:17:42 AMPTE item rework requested by Laker, AndrewPart=12579139, Component=Slide Cavity, Item=E. The reason for rework request was: "E does not have slides. Remove from Tooling Component List."
10/11/2006 9:10:22 AMPTE item rework requested by Laker, AndrewPart=12579139, Component=Slide Cavity, Item=D. The reason for rework request was: "'D' slides have not been completed."
10/11/2006 9:00:35 AMPTE item rework requested by Laker, AndrewPart=12579139, Component=Slide Cavity, Item=C. The reason for rework request was: "Mounting hole for heater return insert has gone missing on 'C' left slide. Reapply hole."
10/11/2006 8:44:50 AMPTE item rework requested by Laker, AndrewPart=12579139, Component=Slide Cavity, Item=B. The reason for rework request was: "No change required on 'B' slides. Remove item from Tooling Component List."
10/11/2006 8:29:53 AMPart 12579139 ApprovedApproved by Laker, Andrew
10/11/2006 8:09:00 AMPTE item rework requested by Laker, AndrewPart=12579139, Component=Mold Plate / Insert, Item=G. The reason for rework request was: "Upper Sprue mold plate was not included in the solution powerpoint attachment."
10/11/2006 7:58:32 AMPTE item rework requested by Laker, AndrewPart=12579139, Component=Mold Plate / Insert, Item=A. The reason for rework request was: "There were no blends to be removed from 'A' lower mold plate. Undo change by reapplying blends. In addition, this CTWR applies to mold plate inserts as well. There are blends that need to be removed on inserts ach43244, ach43242, ach43248, ach44626, ach43490, ach43493, & apu03968."
10/11/2006 7:34:02 AMPart 12579139 ApprovedApproved by Laker, Andrew
10/11/2006 7:28:14 AMPTE item rework requested by Laker, AndrewPart=12579139, Component=Mold Plate / Insert, Item=C. The reason for rework request was: "Incorrect blends were removed. Reapply previous blending & removed bottom edge blends from water jacket/barrel 10mm shut offs."
10/11/2006 7:23:13 AMPart 12579139 ApprovedApproved by Laker, Andrew
10/11/2006 7:10:21 AMPart 12579139 ApprovedApproved by Laker, Andrew
10/11/2006 7:10:09 AMPart 12579139 ApprovedApproved by Laker, Andrew
5/8/2006 3:04:06 PMDC assignment by McCullough, Alex 
5/8/2006 3:03:49 PMDC assignment by McCullough, Alex 
5/8/2006 3:03:33 PMDC assignment by McCullough, Alex 
5/8/2006 3:03:17 PMDC assignment by McCullough, Alex 
4/12/2006 7:35:30 AMAll TMs have approved the request 
4/12/2006 7:35:29 AMTM approval by Meyer, Maurice 
4/11/2006 1:10:12 PMTM approval by Bujouves, Jim 
4/11/2006 6:26:30 AMAll PTEs have acknowledged the request 
4/10/2006 1:33:29 PMRequest submitted, PTE Review required 
4/10/2006 1:18:47 PMRequest created by Laker, Andrew